function ChangeDisplay() { var fSwitchOn = document.getElementById("firstSliderOn"); var fSwitchOff = document.getElementById("firstSliderOff"); var sSwitchOn = document.getElementById("secondSliderOn"); var sSwitchOff = document.getElementById("secondSliderOff"); var imgOn = document.getElementById("firstDisplayON"); var imgOff = document.getElementById("firstDisplayOFF"); var tableOne = document.getElementById("tableOne"); var tableTwo = document.getElementById("tableTwo"); var tableThree = document.getElementById("tableThree"); var buttonsOneTable = document.getElementById("buttonsOneTable"); var buttonsTwoTable = document.getElementById("buttonsTwoTable"); var buttonsThreeTable = document.getElementById("buttonsThreeTable"); var fDisplayOnText = document.getElementById("firstDisplayONText"); var rp3000xtSection = document.getElementById("rp3000xtSection"); if(fSwitchOn.style.display === "none") { fSwitchOn.style.display = "block"; fSwitchOff.style.display = "none"; sSwitchOn.style.display = "none"; sSwitchOff.style.display = "block"; imgOn.style.display = "block"; imgOff.style.display = "none"; tableOne.style.display = "none"; tableTwo.style.display = "block"; tableThree.style.display = "none"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "block"; buttonsThreeTable.style.display = "none"; rp3000xtSection.style.display = "none"; fDisplayOnText.style.display = "block"; } else { fSwitchOn.style.display = "none"; fSwitchOff.style.display = "block"; sSwitchOn.style.display = "none"; sSwitchOff.style.display = "none"; imgOn.style.display = "none"; imgOff.style.display = "block"; tableOne.style.display = "block"; tableTwo.style.display = "none"; tableThree.style.display = "none"; buttonsOneTable.style.display = "block"; buttonsTwoTable.style.display = "none"; buttonsThreeTable.style.display = "none"; rp3000xtSection.style.display = "flex"; fDisplayOnText.style.display = "none"; } }
function ChangeSecondDisplay() { var sSwitchOn = document.getElementById("secondSliderOn"); var sSwitchOff = document.getElementById("secondSliderOff"); var tableOne = document.getElementById("tableOne"); var tableTwo = document.getElementById("tableTwo"); var tableThree = document.getElementById("tableThree"); var buttonsOneTable = document.getElementById("buttonsOneTable"); var buttonsTwoTable = document.getElementById("buttonsTwoTable"); var buttonsThreeTable = document.getElementById("buttonsThreeTable"); if(sSwitchOn.style.display === "none") { sSwitchOn.style.display = "block"; sSwitchOff.style.display = "none"; tableOne.style.display = "none"; tableTwo.style.display = "none"; tableThree.style.display = "block"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "none"; buttonsThreeTable.style.display = "block"; } else { sSwitchOn.style.display = "none"; sSwitchOff.style.display = "block"; tableOne.style.display = "none"; tableTwo.style.display = "block"; tableThree.style.display = "none"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "block"; buttonsThreeTable.style.display = "none"; } }

Automatischer Transferschalter (ATS)

DTSC

DTSC-200A
Automatic Transfer Switch Controller
Auto-Start/ Stop
Auto / manual operation
Remote Start
Open transition transfer
Delayed Transition
Closed Transition Transfer
Mains-Generator application
Mains-Generator, Generator-Generator, Mains-Mains applications
True RMS voltage sensing
True RMS current and power sensing
In-Phase-Überwachung (Synchronisationsprüfung) für alle Übergangstypen
frei konfigurierbare diskrete Ein-/Ausgänge
Einstellbare Schaltuhren
Quellenauswahl
Übergabe-/Rückgabesperre
Parallel erweitert
Lastabwurf und Wiederherstellung
Motortestprogramm (Last/Leerlauf) mit voll einstellbarem Intervall
Interne Schalterverriegelung mit diskreten Eingängen zur Schalterstellungserkennung
PC-Konfiguration & Anzeigekonfiguration
Passwortschutz
Ereignisprotokoll
Programmierbare Logikfunktionen vermeidet Relaislogik oder SPS
CANopen / Modbus-RTU
Produktspezifikation

Automatic Transfer Switch (ATS) Controller - DTSC-200A

The DTSC-200A (Digital Transfer Switch Control) controls the transfer of electrical power from one source to another for hospitals, data centers, office buildings, manufacturing plants and similar where lights out is not an option. The extremely versatile DTSC-200A ATS controller is easily configured for a wide range of automatic transfer switch applications including Main-Gen, Gen-Gen or Main-Main systems using circuit breakers or latch-ing contactors. Source transfer can be performed as open, delayed, or closed transition with in-phase monitor-ing (synch check) that can be enabled for all transition types to ensure safe transfer. The closed transition over-lap time can be limited to less than 100ms for momentary, make-before-break transfers, or extended indefinitely for paralleling via discrete input. “Custom” features like transfer inhibit, source selection, load shed/restore, ele-vator pre-signal and engine test programs come standard.

Zubehör

Configuration Software

Toolkit

Konfiguration über die Woodward standard software Toolkit.

USB

USB-Konfigurationsschnittstelle

USB-Port-Konfigurationsschnittstelle. Die PC/Laptop-Seite ist von der Woodward-Geräteseite durch galvanische Trennung getrennt.

Only needed for DTSC-50 and the old DTSC-200. The DTSC-200A works via a market standard USB-Mini connection. 

 