function ChangeDisplay() { var fSwitchOn = document.getElementById("firstSliderOn"); var fSwitchOff = document.getElementById("firstSliderOff"); var sSwitchOn = document.getElementById("secondSliderOn"); var sSwitchOff = document.getElementById("secondSliderOff"); var imgOn = document.getElementById("firstDisplayON"); var imgOff = document.getElementById("firstDisplayOFF"); var tableOne = document.getElementById("tableOne"); var tableTwo = document.getElementById("tableTwo"); var tableThree = document.getElementById("tableThree"); var buttonsOneTable = document.getElementById("buttonsOneTable"); var buttonsTwoTable = document.getElementById("buttonsTwoTable"); var buttonsThreeTable = document.getElementById("buttonsThreeTable"); var fDisplayOnText = document.getElementById("firstDisplayONText"); var rp3000xtSection = document.getElementById("rp3000xtSection"); if(fSwitchOn.style.display === "none") { fSwitchOn.style.display = "block"; fSwitchOff.style.display = "none"; sSwitchOn.style.display = "none"; sSwitchOff.style.display = "block"; imgOn.style.display = "block"; imgOff.style.display = "none"; tableOne.style.display = "none"; tableTwo.style.display = "block"; tableThree.style.display = "none"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "block"; buttonsThreeTable.style.display = "none"; rp3000xtSection.style.display = "none"; fDisplayOnText.style.display = "block"; } else { fSwitchOn.style.display = "none"; fSwitchOff.style.display = "block"; sSwitchOn.style.display = "none"; sSwitchOff.style.display = "none"; imgOn.style.display = "none"; imgOff.style.display = "block"; tableOne.style.display = "block"; tableTwo.style.display = "none"; tableThree.style.display = "none"; buttonsOneTable.style.display = "block"; buttonsTwoTable.style.display = "none"; buttonsThreeTable.style.display = "none"; rp3000xtSection.style.display = "flex"; fDisplayOnText.style.display = "none"; } }
function ChangeSecondDisplay() { var sSwitchOn = document.getElementById("secondSliderOn"); var sSwitchOff = document.getElementById("secondSliderOff"); var tableOne = document.getElementById("tableOne"); var tableTwo = document.getElementById("tableTwo"); var tableThree = document.getElementById("tableThree"); var buttonsOneTable = document.getElementById("buttonsOneTable"); var buttonsTwoTable = document.getElementById("buttonsTwoTable"); var buttonsThreeTable = document.getElementById("buttonsThreeTable"); if(sSwitchOn.style.display === "none") { sSwitchOn.style.display = "block"; sSwitchOff.style.display = "none"; tableOne.style.display = "none"; tableTwo.style.display = "none"; tableThree.style.display = "block"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "none"; buttonsThreeTable.style.display = "block"; } else { sSwitchOn.style.display = "none"; sSwitchOff.style.display = "block"; tableOne.style.display = "none"; tableTwo.style.display = "block"; tableThree.style.display = "none"; buttonsOneTable.style.display = "none"; buttonsTwoTable.style.display = "block"; buttonsThreeTable.style.display = "none"; } }

Interruptor de transferencia automática (ATS)

DTSC

DTSC-200A
Automatic Transfer Switch Controller
Auto-Start/ Stop
Auto / manual operation
Remote Start
Open transition transfer
Delayed Transition
Closed Transition Transfer
Mains-Generator application
Mains-Generator, Generator-Generator, Mains-Mains applications
True RMS voltage sensing
True RMS current and power sensing
In-Phase monitoring (synch check) for all transition types
freely configurable discrite I/O
Adjustable timers
Source Selection
Transfer / return inhibit
Extended parallel
Load shed and restore
Engine exerciser (load/no-load) routine with fully adjustable interval
Internal breaker interlock utilizing discrete inputs for breaker position detection
PC configuration & display configuration
password protection
Eventlog
Programmable Logic Functions eliminate relay logic or PLCs
CANopen / Modbus RTU
especificaciones del producto

Automatic Transfer Switch (ATS) Controller - DTSC-200A

The DTSC-200A (Digital Transfer Switch Control) controls the transfer of electrical power from one source to another for hospitals, data centers, office buildings, manufacturing plants and similar where lights out is not an option. The extremely versatile DTSC-200A ATS controller is easily configured for a wide range of automatic transfer switch applications including Main-Gen, Gen-Gen or Main-Main systems using circuit breakers or latch-ing contactors. Source transfer can be performed as open, delayed, or closed transition with in-phase monitor-ing (synch check) that can be enabled for all transition types to ensure safe transfer. The closed transition over-lap time can be limited to less than 100ms for momentary, make-before-break transfers, or extended indefinitely for paralleling via discrete input. “Custom” features like transfer inhibit, source selection, load shed/restore, ele-vator pre-signal and engine test programs come standard.

Accesorios

Configuration Software

Toolkit

Parametrización a través del software estándar de Woodward.

USB

SPM-D1040B/NYB

SPM-D2-1040B/NYB

Solo necesario para DTSC-50 y el antiguo DTSC-200. El DTSC-200A funciona a través de una conexión USB-Mini estándar del mercado. 

 

part number: 5417-1251